CURTIS CONTROLLERS
1244
description
Sepex motor electronic controller.
Nominal voltage: 24V, 36V, 48V, 80V
Model 1244-44xx 24V-36V 400A
Model 1244-45xx 24V-36V 500A
Model 1244-46xx 24V-36V 600A
Model 1244-47xx 24V-36V 700A
Model 1244-54xx 36V-48V 400A
Model 1244-55xx 36V-48V 500A
Model 1244-56xx 36V-48V 600A
Model 1244-64xx 48V-80V 400A
Model 1244-65xx 48V-80V 500A
Model 1244-66xx 48V-80V 600A
Operation frequency: 16kHz
error codes
Yellow LED | Description |
1,2 - 1 FLASH + 2 FLASHES | Watchdog circuit active - controller failure |
1,3 - 1 FLASH + 3 FLASHES | M- motor connection shorted to B- or field winding open or armature current sensor fault or firld current sensor fault |
2,1 - 2 FLASHES + 1 FLASH | Throttle fault- pot low or throttle signal out of range |
2,2 - 2 FLASHES + 2 FLASHES | Inproper sequence of keyswitch, interlock input and direction inputs, wrong SRO parameter, sequencing delay too short |
2,3 - 2 FLASHES + 3 FLASHES | High Pedal Disable - inproper sequence of direction inputs and throttle inputs or wrong HPD parameter or misadjusted throttle |
2,4 - 2 FLASHES + 4 FLASHES | Emergency reverse wiring fault- open circuit or emergency reverse check wire open |
3,1 - 3 FLASHES + 1 FLASH | Contactor driver output overcurrent - short circuit |
3,2 - 3 FLASHES + 2 FLASHES | Main contactor welded or its coil driver shorted |
3,3 - 3 FLASHES + 3 FLASHES | Precharge fault - internal capacitor voltage too low at startup |
3,4 - 3 FLASHES + 4 FLASHES | Main contactor coil open circuit |
4,1 - 4 FLASHES + 1 FLASH | Battery voltage too low |
4,2 - 4 FLASHES + 2 FLASHES | Battery voltage too high, overvoltage |
4,3 - 4 FLASHES + 3 FLASHES | Thermal cutback, controller too hot or too cold |
4,4 - 4 FLASHES + 4 FLASHES | Motor too hot or ANTI-TIEDOWN mode is active - Mode input wrong status |