ZAPI CONTROLLERS
COMBI AC0 POWER
description
Inverter for AC asynchronous or BLDC or PMAC or SyncRel motors and DC series motor for pump.
Equipped with CAN-bus interface, flash program memory and 2 microprocessors.
Power AC motor: 2kW - 5kW
Power DC motor: 7kW
Voltages: 24V, 36V, 48V, 72V, 80V
Max. current (24V): 320A or 350A RMS
Max. current (36V-48V): 280A or 320A RMS
Max. current (72V-80V): 200A RMS
Operating frequency: 8Khz
error codes
MDI CAN display | Description |
AL08 | Watchdog, logic circuit fault, software corrupted |
AL17 | Failure in high current hardware protection circuit |
AL26 | Current sensor is damaged |
AL27 | One of motor phases is open |
AL28 | Pump motor output is too low |
AL29 | Pump motor output is too high |
AL31 | Motor output voltage too high |
AL40 | Electrobrake driver is shorted |
AL41 | Wrong battery voltage or wrong Set Battery parameter |
AL42 | Driver of electomagnetic brake is not able to close |
AL47 | Valve 2 driver is shorted or failed |
AL48 | Valve 1 driver is shorted or failed |
AL49 | Lift and lower input both active |
AL50 | Valve 1 coil open circuit |
AL51 | Valve 2 coil open circuit |
AL52 | Pump current is always zero |
AL53 | High phase current at stand-by, wrong voltage on startup |
AL54 | Over or undervoltage condition has been detected |
AL55 | Motor voltage feedback circuits are damaged |
AL56 | Pump motor current sensor out of range |
AL60 | Capacitor charging time is too long |
AL61 | Thermal sensor out of range |
AL62 | Controller has reached thermal cutback temperature (85 deg.C) |
AL65 | Battery low or motor temperature too high |
AL67 | Motor thermal sensor out of range |
AL68 | Smart driver in controller is open or problem with canbus |
AL71 | Eeprom error |
AL72 | Motor output voltage too low |
AL74 | Driver of main contactor or valve coil shorted, coil disconnected, AUX output shorted to positive |
AL75 | Main contactor contact is stuck or electrovalve driver is open |
AL76 | Coil is shorted (contactor, electromagnetic brake, valves) or key-off signal is low at key-on |
AL77 | Contactor do not close or Tiller input mismatch (hard&soft and tiller input) |
AL78 | Accelerator input value too high and direction inputs are open |
AL79 | Incorrect starting sequence |
AL80 | Positive PAUX voltage is not connected- wrong voltage or both travel directions at the same time |
AL82 | Encoder problem |
AL86 | Positive supply to electromagnetic brake is high when tiller switch is opened or accelerator negative wire is open |
AL89 | Short circuit on power transistors or pump accelerator is too high |
AL92 | Maximum current adjustment procedure has not been carried out yet |
AL96 | Problem in microcontroller - analog to digital conversion |
AL98 | Deadman input open |
AL99 | Error on parameters of slip profile settings |