ZAPI CONTROLLERS
H1 DN
description
Chopper for 3 and 4 terminal DC series wound motors.
Power: 0.5kW to 2.0kW
Voltages: 24V
Max. current (3 cables 2Q): 150A
Max. current (all 1Q): 300A
Operating frequency: 18Khz
error codes
RED LED | Description |
1 BLINK | EEPROM error, wrong parameters, watchdog circuit has been trigerred |
2 BLINKS | Incorrect start, wrong sequence - eg. keyswitch, directions, accelerator, function switch active after key-on |
3 BLINKS | Wrong VMN output voltage, short to B- |
4 BLINKS | Accelerator high in standby |
5 BLINKS | Error in read motor current, sensor inside controller |
6 BLINKS | Malfunction of contactor driver circuit |
7 BLINKS | Temperature too high, more than 75 deg. C |
8 BLINKS | Contactors do not close |
32 BLINKS | Battery charge low, less than 10% |
ON | Forward and reverse direction inputs are both active |